The wire gauge necessary will vary based on amperage and distance to the breaker,
but 8 gauge wire is generally sufficient for most installations. If the distance is very
short, sometimes smaller gauge wire may be used. If you aren't sure which gauge of
wire should be used, contact an electrician. The supply wire, main switch and
circuit protection (Leakage Circuit Breaker) must be sufficient for the
amperage required. Please check the table above and the flow rate/temperature
rise chart for the appropriate amperage for your situation. Note that the lower the
amperage, the lower the water temperature rise will be.
DO NOT TURN ON THE BREAKER SWITCH UNTIL ALL ELECTRICAL AND
PLUMBING CONNECTIONS ARE MADE AND WATER IS FLOWING THROUGH
THE UNIT.
Connect (1) white wire to the single pole 10, 20, 30 or 40 Amp circuit breaker.
Connect (1) white wire to the neutral bar on your breaker box. It does not matter
which white wire connects to neutral and which connects to the breaker. Connect
the green ground wire to the ground bar on your breaker box.
Connect the (2) white wires to the double pole 10, 20, 30 or 40 Amp circuit breaker.
Connect the green ground wire to the ground bar on your breaker box.
This appliance MUST be grounded. Connect the ground wire, as indicated in the
Electrical Code.
When all connections are satisfactorily prepared, install the heater cover. With the
insulated container off and water flow modifier (optional) fully open, the faucet must
be opened fully to get maximum water flow . It is necessary to ensure that the water
tank is full before turning the power on. This is an essential step to protect the
heating element.
Note that the above instructions are simply guidelines that apply to most
installations.
The size of the switch and wire gauge must meet all local, state, provincial and
national electrical codes in your area. Contact an electrician if you're not sure.
To determine the minimum electrical circuit please see the next table:
For PP110:
For PP220 (PPXE5):
Remember that the above instructions are just guidelines that apply at most
installations.
Remember that you should remove the red and blue covers before installing your
unit.
Swing Check Valve
Main Water Supply Valve
Green Ground Wire.
Connect to ground bar on breaker box.
POWER PAK - PLUS
Amperage Control Knob
PP110: Connect (1) white wire to
breaker and (1) white wire to neutral.
PP220: Connect both white wires to
breaker.
ONE POINT OF USE TWO OR MORE POINTS OF USE
Power Selector
Minimum Breaker
Position 1 and 2
Position 1, 2 and 3
Position 1, 2, 3 and 4
20 Amperes
30 Amperes
40 Amperes